Multi-controller was upgraded !!
 

 
 

 Heater for generating the high temp. and high pressure hot-air

 New   Spot-heater

Gas is heated quickly from the normal temp. to high temp.!
Max. discharge temp. is 800゚C ,   Resisting pressure is 0.49MPa.

 
Industry first ! Type that A-sensor and B-sensor were incorporated. (All type)
 

MODEL SH01 (Synthesis photo)

MODEL SH31 (Synthesis photo)

 

 

   
 

 
Specification
  Model Type Heater capacity
/ Voltage (Single-phase)
Usable gas capacity Open price Common specification  
SH01 1100-035K 350W/100V About 5 - 120L/min JPY33,600

 * Max. hot-air temp. is 800゚C.

 * Hot-start max. temp. is 500゚C. 
     
 * A-sensor (For detecting hot-air temp.) 
  It is incorporated to the heater element.

 * B-sensor (For hot-start, and  heater
      snapping of a wire prevention) 
    It is incorporated to the heater element.

 * Temp. of supply air is 0 - +70゚C.
     
 * Resisting pressure is 0.49MPa.
   
 * Accessories
   Adiabatic cover (SH11, 21, 31)
     Wiring cord 300mm (SH05,11,21)

 * Proper auto-temp. controller is TRC202.
 

1100-055K 550W/100V
1100-07K 700W/100V
1200-055K 550W/200V
SH11 1100-08K 800W/100V About 10 - 420L/min JPY40,400
1200-06K 600W/200V
1200-08K 800W/200V
SH21 1200-1K 1000W/200V About 10 - 380L/min JPY45,200
1200-1.2K 1200W/200V
SH31 1200-1.5K 1500W/200V About 60 - 1000L/min JPY72,500
1200-2K 2000W/200V
1200-2.5K 2500W/200V
1200-3K 3000W/200V
 
       
  New function installation ! Auto-temp. controller for spot-heater
Multi-controller TRC202
 
 


* Contact output terminal that the abnormal signal is output is installed with addition.
* Temp. control is improved and the performance of 100% of spot-heater was drawn.




 

 
 Specification
 
 * Power supply 
      Single-phase 100V or Single-phase 200V 50/60Hz

 * Heater control capacity 
      Less than single-phase 2kW  (at 100V)
              Less than single-phase 4kW  (at 200V)

 * Max. load current  
      20A (Heater load)

 * Instructions accuracy 
      800゚C plus minus 0.2% FS

 * Control output 
      For heater control (Phase control)

 * Function  
      Outlet hot-air temp.  A-sensor  Normal - 800゚C
      Hot-start temp.  B-sensor  Normal - 500゚C
      Overheat prevention temp.
                 (Heater snapping of a wire prevention)  B-sensor  700゚C fixed
      ON/OFF of the heater by the outside signal
      Change of the operation mode by the outside signal
                 (Hot-start / Normal operation)
      With contact output terminal
                 (Selection from 5 mode of the output terminal function)
      Temp. alarm function
      Auto-tuning function


 * Open price
      JPY98,0000
 

Specification are changed without that tells to improve performance.

 

Catalog of this product is ...

     

Get the catalog just now

     

Operation manual of
this product is ...

     

Figure of this product is ...

     

Selection of the hot-air
 generator is ...

 
 

     

     

     

     

 

                                     

 

Return to Main menu

Contact us